Interface Module Crestron TPS-6X-IMCW
Connectors, Controls, & Indicators (Continued)
# CONNECTORS
1
,
CONTROLS &
INDICATORS
DESCRIPTION
6 LAN
(1) 8-wire RJ-45;
10/100BASE-T Ethernet port
TYPE PIN SIGNALS
1 TD+
2 TD-
3 RD+
4 N/C
5 N/C
6 RD-
7 N/C
8-Position
RJ-45
8 N/C
7 GROUND
4
(1) Flying lead, grounding wire
1. Interface connectors for NET and VIDEO IN ports are provided with the unit.
2. May be powered by power pack (sold separately) or Cresnet network power, not
both. Be sure to use a Crestron approved power supply as another may cause
damage.
3. Balanced and unbalanced video inputs are mutually exclusive.
4. A grounding lead is provided for connection to earth ground (building steel). This
ground connection is recommended to provide a common ground reference for
signals provided to the TPS6X-IMCW, notably video inputs and to reduce the
incidence of possible damage to the unit from static discharge.