Crestron C2N-MNETGW infiNET™ Gateway/Transceiver
Operations Guide – DOC. 6317B infiNET™ Gateway/Transceiver: C2N-MNETGW 17
Operation
Operating
Channel
The RF channel mode of the C2N-MNETGW must be set prior to
operation using Crestron Toolbox. The C2N-MNETGW can operate on a
fixed channel that is set by the installer or it can automatically set itself to
the clearest channel. The C2N-MNETGW can operate on one of 16
channels.
1. Establish communication with the C2N-MNETGW as described in
“Establishing Communication” on page 15.
2. Select Functions | MNET Gateway... to open the
C2N-MNETGW’s controls.
C2N-MNETGW Controls
3. Set the RF channel mode and the RF channel (if operating in the
Fixed mode).