Crestron TPS-4500IMPC Interface Module
Wire Gauge Values
RESISTANCE (R) WIRE GAUGE
4
16
6
18
10
20
15
22
13
Doubled CAT5
8.7
Tripled CAT5
NOTE: When daisy-chaining Cresnet units, strip the ends of the wires
carefully to avoid nicking the conductors. Twist together the ends of the
wires that share a pin on the network connector, and tin the twisted
connection. Apply solder only to the ends of the twisted wires. Avoid
tinning too far up the wires or the end becomes brittle. Insert the tinned
connection into the Cresnet connector and tighten the retaining screw.
Repeat the procedure for the other three conductors.
Hardware Hookup
The TPS-4500IMPC serves as an interface between the touchpanel and
the Cresnet system. Refer to the illustration after this paragraph for
proper connections; apply power last. When making network connections
to a control system or Cresnet peripherals, refer to “Network Wiring” on
page 5. It is not necessary to make connections to a video source unless a
TPS-4500V touchpanel is used or a TPS-VID-1/2 has been installed into
a TPS-4500 touchpanel and a video window object resides on a page
within the uploaded Crestron VisionTools
®
Pro-e (VT Pro-e) project.
NOTE: When connecting the net/video cable from the interface module
to the touchpanel, exceeding a cable length of 30 feet will significantly
degrade the video signal. To maintain high-quality video, DO NOT
daisy-chain cables or Crestron TPSBLOCK-10 cables longer than 30
feet. Contact Crestron for the maximum available cable length.
Operations Guide - DOC. 6163 Interface Module: TPS-4500IMPC 7