A. Clock/date activation
- DST format 4 for Europe (only with 2-series!, otherwise leave open)
- Serialize date (7 formats) sends out text string to be displayed in a normal text field
-Symbols: Clock driver, Serialize Date (Date$)
- The date “Text” string is only send at program startup or at midnight, update
possibility via the [INIT] function on the date symbol
B. Subpages
Subpages (4,5,6) are made
visible by a high digital signal.
In this case the Interlock
symbol provides this high
signal and so keeps the
“feedback” high.
(*)Full pages can also be
given join numbers, but in the
contrary to subpages they
just need a digital pulse to be
made visible and stay visible
= alternative page flip!