Crestron SIMPL+ Información técnica

Busca en linea o descarga Información técnica para Software Crestron SIMPL+. Crestron SIMPL+ System information Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 90
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Main Page Related Pages
SIMPL Windows Release notes:
Introduction
Congratulations! You have received a copy of Crestron's SIMPL Windows software package. This exciting
program builds programs for Crestron control systems, both with a graphical programming environment
called SIMPL and a procedural language called SIMPL+ for more advanced programmers.
Crestron has devoted a great deal of time and effort to make sure that the software you receive is "ready for
primetime." If you have any comments or suggestions, we would appreciate hearing from you by email at
software@crestron.com. (Technical support questions should continue to go to our telephone hot line at 1-
888-CRESTRON.) If you cannot email us, you can also give us your feedback via the telephone or fax. If you
are experiencing problems, Crestron's top-notch technical support team is standing by to help you at 1-888-
CRESTRON.
The following sections are available in the release notes:
General Notes and Issues
New SIMPL Windows Features
Installing the Crestron Database
Installing the SIMPL+ Cross Compiler
Installing the Crestron Toolbox
General Notes and Issues
Special Note for Windows XP Service Pack 2 Users
It has been discovered that Windows XP Service Pack 2 causes a memory leak with applications that use the Microsoft
Foundation Classes (MFC). This can be seen by using Task Manager to watch the allocation of GDI objects by the
application when child windows are created and destroyed. Since Crestron Toolbox uses MFC it is affected by this issue
and may eventually crash after a large number of windows are opened and closed. Microsoft is aware of this problem and
has issued Hotfix KB319740 to address it. For more information and to download the patch, please see:
http://support.microsoft.com/kb/319740/en-us
It is not neccessary to install this patch, unless you feel you are seeing this issue as it is not likey to come to the point of
crashing the application due to the limited use of these resources by Crestron Toolbox.
General Notes:
Display of "(C:xx H:yy)" in Program Tree and System Configuration Tree: The F11 Key (when pressed while the
Program Tree on the Program Manger page is active, or when the System Tree on the Configuration Managemer
page is active) will toggle the display of some debugging information. This information will appear in the format of "
(C:xx H:yy)" after the symbol or device name. This data can aid Crestron support personnel in troubleshooting
problems andcan be very helpful for problem resolution but is meaningless to the programmer, and harmless to
display.
SIMPL Windows 2.10.XX (and later) SUGGESTS the following software to be installed to ensure importing as much
VTPro-e data as possible when associating an user interface device with a VTPro-e project:
VTPro-e 3.7.0.7 or later (refer to specific hardware documentation for version required by specific devices)
Crestron Database 18.7.5 or later.
Crestron Toolbox 1.07.00 or later.
Known issues:
Replace Control System with sub-slotted devices:
Any programming on sub-slotted device cards that are fixed may not get copied over, even if the new
Control System is the same or has the same fixed cards (e.g. programming on the AADS XM Tuner
card does not get copied over if converting from an AADS-XM to an AADS.)
Serial drivers may have issues when converting to or from AES, AADS, or AADS-XM
The Parameter Properties dialog will allow incorrect data to be entered for Ranges and Default Values for
items that are a Decimal format. If a Default Value is acutally an illegal value (e.g. a Decimal item with a
floating point entry), it will not be assigned to that parameter when the module is added to the program. If a
Range is an illegal value, data entry checking may not be correct. Until this is fixed, make sure Ranges and
Default Values are legal. Refer to the Numeric Formats section of the Help to determine legal values.
Vista de pagina 0
1 2 3 4 5 6 ... 89 90

Indice de contenidos

Pagina 1 - SIMPL Windows Release notes:

Main Page Related PagesSIMPL Windows Release notes:IntroductionCongratulations! You have received a copy of Crestron's SIMPL Windows software pac

Pagina 2 - Explorer

Fixed padding with leading 0's within string format specifiers.Fixes for RetimeWait().Fixes/Changes from 3.00.54 to 3.00.55:SIMPL Windows Bug Fix

Pagina 3 - New SIMPL Windows Features

SIMPL+ Bug Fixes (3 Series):Support for Direct SocketsFixes/Changes from 3.00.40 to 3.00.42:SIMPL Windows Bug Fixes:Resolve issue with invalid 3 serie

Pagina 4

Fixes/Changes from 3.00.31 to 3.00.33:SIMPL Windows Bug Fixes:Fix issue with COM port information extender. If the COM port has no signals, the COM po

Pagina 5

Correct issue where SIMPL+ parameters were off by 1.3 Series compilations now say "LPZ" instead of "SPZ" on the compilation dialog

Pagina 6

Fixes/Changes from 3.00.17 to 3.00.18:SIMPL+ Bug Fixes (3 Series):Fix incorrect translation of HIGH function.Fix incorrect translation of LOW function

Pagina 7 - #DEFAULT_VOLATILE

Fixes/Changes from 3.00.10 to 3.00.11:SIMPL Windows Bug Fixes:Correct issue where the SIMPL symbol for a SIMPL+ module had the wrong DLL name in it&ap

Pagina 8

"Please start SIMPL Debugger from the Toolbox instead. Start Toolbox, click on the Tools menu and select "SIMPLDebugger. Set the address of

Pagina 9

Initial release to support the MC3 Platform.Fixes/Changes from 2.12.31 to 2.12.32:SIMPL Windows Bug fixes:Fixed issue with F9 (search/replace) not upd

Pagina 10

SIMPL+ Bug fixes:Fixed an issue in SIMPL+ with the _SKIP_ command was not being processed correctly in parameter definitions.Fixes/Changes from 2.12.2

Pagina 11

SIMPL Windows Bug fixes:Fixed problem with copying a group of inputs or outputs where there were some items that didn't have signals. Theitems wi

Pagina 12

There have been times when running SIMPL Windows on the Microsoft Vista operating system, thatcompiling a program may result in errors stating that SI

Pagina 13

left/right arrow keys.Fixed bug where selecting a signal from the Routings dialog didn't always show and highlight the signal in theassociated de

Pagina 14

Crestron Devices.F6 will now be the hotkey to use to display the Configuration dialogs of a device in the System Configuration tree,on the Configurati

Pagina 15

SIMPL Windows Bug Fixes:Fixed bug where trying to open and exit a Module Header dialog sometimes issued an error message.Fixes/Changes to 2.11.07 to 2

Pagina 16

For signal names that are automatically generated by SIMPL Windows to represent the symbol and cue to whichthe signal is attached, the number of chara

Pagina 17

program.Updated Version Information on the Help->About dialog to show path where data files are located.The View menu will now show the number of s

Pagina 18

Removed "Live Update At Startup" from Options menu, the Help menu and from the Toolbar. "Live Update" is beingreplaced with the Ma

Pagina 19

Expose System Builder model for AMS-AIPExpose TPMC-4XGExpose Windows SideShowFixes/Changes to 2.10.28 to 2.10.29:SIMPL Windows Bug Fixes:Fixed error w

Pagina 20

that might have been done on the device symbol was being cleared.Restored the View menu options of Expand All, Collapse All, Expand Current Node and C

Pagina 21

TPS-12G-QM System2 Reserved JoinsTPS-15G-QM System2 Reserved JoinsTPS-15 System2 Reserved JoinsTPS-17 System2 Reserved JoinsAdded Digital InputsLcd Br

Pagina 22

SVID Safe Tv Setup MaxAdded Digital OutputsSVID Safe Tv Setup None_fbSVID Safe Tv Setup Min_fbSVID Safe Tv Setup Max_fbTPS-12 Composite-1 Control Rese

Pagina 23

what the Symbol Tree category (#Category in SIMPL+) is not 0. Often modules will be set to 0 if they areused as part of other modules so as not to clu

Pagina 24

Removed Digital InputsYPbPr-1 Hue UpYPbPr-1 Hue DownRemoved Analog InputsYPbPr-1 HueRemoved Analog OutputsYPbPr-1 Hue_fbTPS-12G-QM YPbPr-2 Control Res

Pagina 25

SIMPL Windows Bug Fixes:Fixed error in parameter validation that was rejecting any value in seconds that did not have a number precedingthe decimal po

Pagina 26

There were cases where, even though the "Allow stacking" option (will allow one 1way Serial driver on sameport as IR Drivers) was disabled,

Pagina 27

reopened. Now, if any subfolder has a protected module below it, the subfolder can no longer be deleted.Any non-protected symbols below that subfolder

Pagina 28

Fixed a problem with losing the first character of a Symbol comment when entering the comment via the status bar.Fixed problems with selecting multipl

Pagina 29

AADS 1 Way Serial Driver can now be dropped on AADS IR Ports.Correct Help ID for AMS Surround Sound SlotIncrease number of joins on AMS Screen Feedbac

Pagina 30

Fixes/Changes to 2.10.09 to 2.10.10:SIMPL Windows Bug Fixes:Fixed error where modules selected to have GUI connection logic via the Module Header dial

Pagina 31

CEN-RGBHV12x4CEN-RGBHV12x8Correct AAS models to remove "Day 3" labels.INCLUDE.DAT 1.58SetByte() functionFixes/Changes to 2.10.08 to 2.10.09:

Pagina 32

Library Update Version 498:Rename "C2N-FTB" to "C2N-FTB/C2N-FTDAC"INCLUDE.DAT version 1.57:Correct internal function that could ca

Pagina 33

Fixed error in validation of percentage parameter values that was causing SIMPL to crash either during the entry ofa percent value or, during compile

Pagina 34

Fixes/Changes from 3.01.40 to 3.01.41:SIMPL Windows Bug Fixes:Fix issue with RSD's complaining about Core 3 UI Components.Changes for Fusion (aka

Pagina 35

XGen version of the TCP/IP Client module was being used and as such, not all cues required by 2-series werebeing brought in to the connection logic.Fi

Pagina 36

If the group is currently expanded, the input/output cues and programmed signals in that group will beshown. There will be a "-" displayed i

Pagina 37

SIMPL+ Bug Fixes:Correct Issues with parameter properties with "unitTicks" and "unitCharacter"Correct Issues with compilation when

Pagina 38

Fix MPS-200 System Builder model compilation issue.Fixes/Changes from 2.08.37 to 2.08.38 - PUBLIC WEB SITE RELEASE:SIMPL Windows Bug Fixes:Fixed a pro

Pagina 39

Fixes/Changes from 2.08.34 to 2.08.35:SIMPL Windows: Fixed SIMPL Debugger scrolling and window size issues.SIMPL Windows: Update to library 465 (Inclu

Pagina 40

Fixes/Changes from 2.08.30 to 2.08.31:SIMPL+: Fix issue where targets would be rebuilt even if they were up to date.SIMPL Windows: Correct crash on ex

Pagina 41

was if they were a subslotted device to a Cresnet or Ethernet device. Now, only the top level Ethernet or CresnetDevices will be avaialable and, if th

Pagina 42

symbol to be added to the Detail view to automatically be tiled Horizontal or Vertical, they must go to the View menuand make the appropriate selectio

Pagina 43

SIMPL Windows: Fixed problem with Highlighted signals not showing up on Print Preview or printouts.SIMPL Windows: Fixed problem with not being able to

Pagina 44

STRING Inputs/Output variables were being declared. This also affected the expansion of Input/Output Arrays.Library Update 428Update C2N-IRGW Firmware

Pagina 45

Fixes/Changes from 3.01.26 to 3.01.29:SIMPL+ Bug Fixes:Implemented support for ENABLE_TRACE and PRINT_TO_TRACE (in modules and libraries); 3 Series Fi

Pagina 46

SIMPL Windows: Added "Import User Interface Logic" support to subslotted devices that have User Interfacedevices below them.SIMPL Windows: F

Pagina 47

specified Input, Paramter or Output in the Detail View. The value entered by the programmer is based on Absoluteinput/parameter/output numbers. In oth

Pagina 48

Icons: Icons for modules that have any kind of Default Logic (for User Interface devices, Cresnet/Ethernet devicesor Front Panel objects) will have di

Pagina 49

TPMC-15-CH (Ethernet)TPMC-15-QM (Ethernet)TPMC-17-CH (Ethernet)TPMC-17-QM (Ethernet)UPX-2 Ethernet (All Variations)Fix HelpIDs for:"Packet Transm

Pagina 50

Add "Annotation Reserved Joins" to the following panels (No help available yet)TPS-12G-QM (Cresnet, Ethernet)TPS-15G-QM (Cresnet, Ethernet)T

Pagina 51

Fixes/Changes from 2.07.22 to 2.07.24 - PUBLIC FTP SITE RELEASE:SIMPL Windows: Fixed an issue with not being able to drag and drop signals from the De

Pagina 52

Arguments symbol as appropriate. Please refer to the on-line Help for more details. Module Header Dialog: Createda new Module Header Tab for entering

Pagina 53

Toolbox.If the compiled program is too large to fit in internal Flash & the processor does not support Compact Flash, thefatal error RLCMCVT201 is

Pagina 54

Fixed bug when using a Structure STRING element within MakeString(). Spaces were being stripped from theformat string. Ex: - MakeString(MyStruct.MyStr

Pagina 55

Fixes/Changes from 2.06.15 to 2.06.16:SIMPL Windows: Fixed bug that could potentially cause SIMPL Windows to crash when saving a program file after ha

Pagina 56

SIMPL+ Bug Fixes:Fixed translation issue when calling functions within expressions.Fixed bug when compiling modules with libraries for both 2 and 3 se

Pagina 57

Fixes/Changes from 2.06.07 to 2.06.08:SIMPL Windows: Fixed crash that can sometimes occur when trying to access Serial Upload Settings dialog ondevice

Pagina 58

Fixes/Changes from 2.06.01 to 2.06.02:SIMPL Windows: Fixed Processing of default RF ID's.Library Update (v317 and later): Expose the following sy

Pagina 59

RF or IR device existed on a Built-In Gateway card on the source control system.SIMPL Windows: Fixed problem where the wrong signal was getting delete

Pagina 60

devices do not support that.Viewport: Changed text during status callback for "Storing new firmware" to add "Do NOT disconnect during t

Pagina 61

Fixes/Changes from 2.05.19 to 2.05.20 - PUBLIC FTP SITE RELEASE:SIMPL Windows: Fixed problem with not being able to swap Serial Devices within a Seria

Pagina 62

SIMPL+: Add file encryption for X Generation SIMPL+ compiler.SIMPL Windows: Analog Input Properties, Analog Output Properties and Parameter Properties

Pagina 63

SIMPL Windows: Add proper device extenders to CN-TVAV Remote Processing, C2N-DAP8, C2N-DAP8RC, andC2VEQ-4 (Also in library update 251 and later).Viewp

Pagina 64

SIMPL Windows: Fixed problem with user database not allowing .IR files with names longer than 50 characters.SIMPL Windows: Fixed SIMPL Windows crash w

Pagina 65

same password. If not encrypted, the new file won't be encrypted).SIMPL Windows: Fixed issue with "Edit Module" not bringing up the Sim

Pagina 66

top of the cresnet card or the ethenet card and have the plus sign show it as a potential valid drop. This is the wayit is with other cresnet and ethe

Pagina 67

SIMPL+ Enhancements (Refer to help file for usage):Threadsafe keyword for non-reentrant push, release, change events in SIMPL+ (3 Series only)Fixes/Ch

Pagina 68

Simpl Windows: Fixed system crash when trying to compile a program that had an empty (i.e. no symbols) modulenested within another module.Viewport: Fi

Pagina 69

SIMPL Windows: Removed display of "Logic Node Commented Out" warning message every time a program with aTPS Series Panel as the control syst

Pagina 70

SIMPL Windows: Fixed issue with the end of some Module Comments being lost when the comments were reallylong.SIMPL Windows: Fixed problem on Copy to C

Pagina 71

Fixes/Changes from 2.04.07 to 2.04.08:Internal build only - not released.Fixes/Changes from 2.04.06 to 2.04.07:SIMPL Windows: Added 'Live Update

Pagina 72

Fixes/Changes from 2.04.03 to 2.04.04:SIMPL Windows: Completed support for Property definitions for all types of Inputs/Outputs and Parameters. Todefi

Pagina 73

Viewport: Added support for setting the control system Domain Name.Viewport: Added support for reconnecting by hostname.domainname when enabling DHCP.

Pagina 74

SIMPL+: The compile output window will indicate if it is skipping the module's compile if it is already up to date.SIMPL+: Fixed control system c

Pagina 75

SIMPL+: 'Total Memory Used' is no longer displayed after compilation (Total NVRAM is still calculated & displayed)Viewport: Fixed crash

Pagina 76

SIMPL+: Fixed SetArray for local integers and long integers (signed & unsigned).SIMPL+: Allow string function arguments to be passed into Remove()

Pagina 77

and the device is not added.Updated processing for PDF help files (help via the Device Library AND the Help Menu->Control CD ProductDirectory) to n

Pagina 78

Trap I/O Variables within File Read/Write functions. 3-Series gives error, 2-Series gives warning.Fixed translation bug for SetGMTOffset for negative

Pagina 79

Fixes/Changes from 2.03.08 to 2.03.09:Fixed crash from editing a front panel after a replace control system has been peformed.Added "Refresh"

Pagina 80

Ethernet Intersystem Communication device before an Export operation, as this will be needed for the 2 systems tocommunicate. Importing a Remote Syste

Pagina 81

2.02.XX versions.Fixed problem with AppBuilder not getting complete lists of potential controllers for a Serial device.SIMPL+: Fixed problems with usi

Pagina 82

Move CNXRMIRD from "Card Slots -\> Room Box Accessories" to "Wireless Receivers -\> IR"Fixes/Changes from 2.02.06 to 2.02.07

Pagina 83

Changed wording on the Power Usage dialog.Add "Connection_Status" output to e-Outlook interface.Fixed problem where App Builder was adding a

Pagina 84

SIMPL+: Changed keyword LONG_FUNCTION to LONG_INTEGER_FUNCTION.SIMPL+: Added SIMPL+, Include.dat and Cross Compiler version information to .USH file.M

Pagina 85

Added Compact Flash File FunctionsAdded LONG_FUNCTION function type (returning LONG_INTEGER types from functions)Allow Structures and LONG_INTEGER dat

Pagina 86

AFORCE, ACAST), Serial Force (Speedkeys: SFORCE, SCAST), and Digital Force (Speedkeys: DFORCE,DCAST). These symbols can be placed in a program and con

Pagina 87

Fixed help links for various Ethernet devices.Fixes/Changes from 2.00.28 to 2.01.00:Fix compilation of CNXIR-8 cards in a 2 Series control system when

Pagina 88

Fix compilation of the UP and DOWN arrow buttons on the front panel (2 Series only)Fix so that Application Builder can upload to a 2 Series system. Th

Pagina 89

try/catch support (3 Series Only)New functions: GetExceptionMessage(), GetExceptionCode()New compiler directives: #IF_SERIES2, #IF_SERIES3Command line

Pagina 90

Features introduced in Version 2.00.16 include:Support for the 2-Series control systems in SIMPL Windows itself, Viewport, Test Manager.New Symbols ad

Comentarios a estos manuales

Sin comentarios