Crestron TPS-RFGWX Two-Way RF Transceiver
Operations Guide - DOC. 5847A Two-Way RF Transceiver: TPS-RFGWX 9
NET ID assignment must match the assignment made in the SIMPL Windows
project. In addition, a Low Power Mode setting lets you reduce the transmission
power to reduce or eliminate interference with other RF devices communicating with
or near the Cresnet system.
NET ID
For a definition of Viewport,
refer to the Note on page 12
Every piece of equipment and user interface within the Cresnet system requires a
unique NET ID. These codes are two-digit hexadecimal numbers from 03 to FE. The
NET ID of the unit must match the NET ID specified in the SIMPL Windows
program. The NET ID of the TPS-RFGWX is factory set to 52. The NET IDs of
multiple TPS-RFGWXs must all be unique and changed from a PC via the Crestron
Viewport. To set or change the NET ID of the TPS-RFGWX, complete the
following steps.
1. Attach only one TPS-RFGWX to the control system (verify that the
software is running).
2. Open the Crestron Viewport (Version 3.53).
Either launch the stand-alone version of Viewport, or start SIMPL
Windows or VT Pro-e, and from the menu bar, select Tools |
Viewport.
3. From the Viewport menu, select Functions | Set Network ID. The
software checks the baud rate and then opens the “Set Network ID”
window.
4. In the “Set Network ID” window, select the TPS-RFGWX from the
Current Network Devices text window.
5. From the Choose the new network ID for the selected device (Hex):
text box, select the new Net ID for the TPS-RFGWX.
6. Click Set ID to initiate the change. This will display the “ID
command has been sent” window.
7. In the “Command Complete” window, click OK.
8. In the Current Network Devices text window, verify the new NET ID
code.
9. In the “Set Network ID” window, click Close.
NOTE: The new NET ID code may also be verified by selecting Diagnostic |
Report Network Devices in the Viewport.
10. Attach each TPS-RFGWX to be added to the Cresnet system
individually and repeat this procedure as needed.
Channel ID, Band, and Power Setting
Each gateway communicating with a touchpanel must have a channel ID and band
assignment that matches the RF channel and band assignment of the touchpanel.
There are 16 possible channels ranging from 0 to F (hexadecimal number) and the
channel assigned to each touchpanel must be unique. Similarly, there are 10 possible
bands that can be selected, and the selection made for the touchpanel and the
gateway must match. Also, if two or more gateways are operating in close proximity
and experiencing interference problems, you can select the Low Power Mode to
reduce signal strength, which may eliminate the interference.