CmVptLib32.dll (1.01.12)
VptComServer.exe (1.01.12)
CmVptGui.dll (1.1.0.5)
Devices.ini (29)
Macros.ini (20)
Program Tree Control (4.0.0.2)
Network Tree Control (4.0.2.0)
Reference Documentation
Bugs Fixed:
Macros.ini - fixed meshent repeater support for proper tree
display.
Devices.ini
Added TPMC-10-DSW support
Added CNX-RMC/LV support for reporting version properly
only.
Added CLW-xxx support as CLW boot laoder
Added L versions for TPS-12, 15 and 17.
Added key for program tree set id methods for CLS-C6(M)
Changed GenericConsole device type so no <CR> is sent
automatically.
In Subnetwork detection
If duplicate IDs were found, then further sibling networks
were not checked. This is almost correct, but should be
child networks rather than sibling networks.
If duplicate IDs are found on a subnetwork of an indirect
session, add an additional 'error' message noting the
indirect type and id of that parent.
Added a call to GetValidIDRange instead of assuming 03-FE
when checking for invalid IDs.
TSDeviceMasterParseDeviceResponse - Added converted serial
number as an extra parameter to outputs.
TSDeviceMasterSetCresnetIDByTSID - Added a range check for
valid cresnet ids of 02 to FE. We allow 02 since at this
Added a EAmManual method for Console mode which does not
send a CR.
Meshnet related
MeshnetMasterReportDevices for Subnetwork detection -
Filter out anything at id 01 since it should not be referenced
by that id anyway. This should cause reference by TSID.
MeshnetSlave_MeshnetNoID method added with
GetValidRange returning 01,01 for min,max, and unmapped
support for SetID. ClearID, GetID, and GetIDRange all still
6/1/2011 Crestron Toolbox: Crestron Toolbox Rele…