While using the QM Audio Config Tool, if you have a text
cosnole open to the same device over cresnet, some
operations and updates may be slower than usual. To
correct this, close all text consoles while using the QM Audio
Config Tools.
Regarding the "Allow 16-level fonts to load" check box on
the Touch Panel Project Dialog. VTPro uses this standard
project dialog so the setting WILL be in effect. The only
stipulation is that VTPro can be set to auto-load the project
in which case the dialog does not give the user a chance to
change settings and just starts loading immediately. In this
case it may be missed, or they will have to turn off the
auto-send to have a chance to change the setting. The
setting will be persistent in this case. So if they uncheck
then turn auto-send back on, it will continue to send only
the 4-level fonts. Loads through System Builder and D3Pro
do NOT use this standard dialog and therefore will always
attempt to load 16-level fonts if the panel supports them,
regardless of the state of this check box. To specify this
setting in scripting see the command
ability_functions_DisplayListSetSpecialLoadBehavior. Also
note that some models of touch panels have a command to
disable 16-level font support wchich if done, will override
any Toolbox setting and prevent the 16-level fonts from
loading. See the release notes of the latest FW for your
Touch Panel for details.
Regarding DM Tool for DigitalMedia. While the DM Tool is
running, if the connected device (DM Switcher) experiences
a reboot for ANY reason The DM Tool will no longer show
correct status updates. In this case you should close all
Toolbox tools and Apps (including SIMPL Windows, System
Builder, VTPro-E) and then relaunch the DM Tool.
All Tools: if multiple instances of a tool are opened, then
one is closed, all other open instances will not work
correctly. If this occurs, close down all open tool instances,
then open a new tool instance to have full functionality
restored.
The following issues involving Toolbox have work arounds or
posted fixes, and therefore will not be fixed.
The SMW Program Tree may not show proper menu items
for certain devices which cannot be programmed in SIMPL
windows. This includes but is not limited to the AES. A fix
for this issue has been included in SIMPL Windows 2.07.21.