Crestron TPMC-10-DSW Guía de instalación Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
Docking Assembly for TPMC-10 Crestron TPMC-10-DSW
Expanded MC2E System Tree
C2Net-Device Slot in Configuration Manager
In Configuration Manager, drag the TPMC-10-DSW from the Cresnet I/O Control &
Other Modules subfolder of the Touchpanels folder in the Device Library and drop it
on the Cresnet Units symbol in System Views. The MC2E system tree displays the
TPMC-10-DSW in C2Net-Device, Slot 1, with a default Net ID of 22, as shown in
the following graphic.
C2Net Device, Slot 1
Setting the Net ID in Device Settings Window
Double-click the TPMC-10-DSW icon in the upper pane to open the “Device
Settings” window. This window displays TPMC-10-DSW device information. Select
the Net ID tab to change the Net ID, as shown in the following graphic.
Docking Station “Device Settings” Window
NOTE: This procedure sets the Net ID for the docking assembly in the program
only. It does not automatically set the Net ID for the docking assembly itself. SIMPL
Windows automatically changes Net ID values of a device added to a program if a
duplicate device or a device with the same Net ID already exists in the program.
Always ensure that the hardware and software settings of the Net ID match. For Net
ID hardware settings details, refer to “Identity Code” on page 5.
10 Docking Assembly for TPMC-10: TPMC-10-DSW Operations and Installation Guide - DOC. 6400