• Various report improvements
• Various minor enhancements
Fixed Bugs
• GLS-SIM added to Bill Of Materials properly
• In Load Schedule View, tree will now scroll automatically when dragging a load
beyond tree boundary.
• The 2nd gateway is highlighted by default instead of the current gateway.
• Allow time and date columns in Real-time View
• Mouse hour glass cursor appears throughout process of Copy/ Paste
• Fixed bug where Paste Special did not work from list area in Interfaces View
• Eliminated erroneous warning when changing time of new scheduled event
• Now able to import existing TPMC-8X VTPro-e projects
• Fixed bug where buttons using the Tap, Hold, or DoubleTap events that were
exported to a remote system could not be triggered from the remote processor
• Fixed bugs which could cause custom Touch-panel logic to be lost in various
situations
• Fixed bugs with simulated keypad button presses from within Real-time View
• Fixed preset synchronization bug where there were loads in the preset which were
not assigned to any control module
• Fixed rare bug that could result in a project that would not open, after replacing a
CAEN-7x1 with a CAEN-4x1 enclosure (issue may have occurred with other
replacement combinations as well)
• Numerous minor bug fixes
v2.6.15
• Added support for the DIN-rail modules and enclosures in “Module and Enclosure
View”.
• Added support for the DIN-rail product line to the “Module Assignment Wizard”.
• Added support for the CLS-EXP* line of expansion modules.
• Added “0-10V External Dimmer” and “0-10V LED Driver” loads. These loads are
intended to be controlled via the DIN-AO8 module.
• Enhance support for new keypad modules. Now D3 Pro will use the built-in Tap,
DblTap, and Hold events provided by most new keypads. D3 Pro will also use the
built-in blink patterns to generate the blinking effects during lighting fades and delays.
• Added the “Tap and DblTap” and “Tap, Hold, and DblTap” button models.
• Added “Search” box to the drop-down list in Module and Enclosure View. This
provides a fast way of locating loads when assigning them to modules. Searches for
load name, area/room name, and controlled circuit number.
• Added a “Replace With…” feature for enclosures. This allows enclosures of similar
types to be swapped out easily (e.g. CAEN 4x1 for a CAEN 7x1).
• Added a “Status” field for all loads. This field can be used during system
commissioning to help keep track of which loads have been confirmed as wired
correctly, which have been confirmed to be wrong, and which have not yet been
checked.
• Added shortcuts to locate lighting loads from the Programming View. Right-click on a
programming step that targets a load, and the context menu will have “Show in Load
Schedule” and “Show in Module View” options.
• Added an “Engraving” report, which simply shows a picture of all selected engraved
products in the project.
• Changes made by the end-user to scheduled events can now be synchronized back
into the D3 Pro project file. During the synchronization process, D3 Pro displays the
differences for each event and allows the user to choose which events to