Crestron D3 PRO Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
Fixed bug where in certain cases the Override levels set on modules were being
cleared.
Fixed bug where the “_File Location_” parameter was not being set on devices,
meaning that some devices would store data to a default location, rather than
obeying the location specified in the System Properties dialog.
Fixed bug where attempting to turn on Real-Time Mode while no control processor is
connected would attempt to start the synchronization process.
Fixed bug where program generation would fail for projects containing > 500 loads
marked as “Record”.
Fixed bug where deleting a device from a “list” (various Views) would cause the focus
to jump to a “random” device. Now focus is shifted to the next item in the list, when
possible.
Warning dialog that appears after program generation is now resizable.
Fixed bug where Most Recently Use file list (File Menu) was not updated when a
project was opened and the user only clicked on Build Program.
Fixed bug where clone buttons wouldn’t indicate that they are “programmed” (i.e.
appear in bold) until the View was changed and then reentered (only applied to non-
graphical programming interfaces such as the CLW-DIM4RF).
Preset Synchronization file does not include unattached loads.
Fixed issue when enter out-of-range join number.
Fixed bug when initially select Multi-Press button model.
v2.5.5
Fixed bug where application could crash when editing conditional expressions
involving certain devices (e.g. Cameo 2 keypad).
v2.5.4
Properly handle discontinued products regarding the Bill Of Materials. Also improved
the Bill Of Materials reports to distinguish between discontinued products and those
for which pricing info is missing.
v2.5.3
Fixed bug (introduced in v2.5.2) where application would crash when editing lighting
levels from the "Adjust Lighting" grid in Programming View.
v2.5.2
Fixed bug where application would crash when the "Page" button on the ML-600
remote was clicked on when an empty Group was selected.
Improved message that appears when Sync Learned Lighting is attempted with no
communications to a processor established.
Added support for new device types, including Cameo Version 2. (NOTE: actual
support for this or other devices also requires an appropriate version of the Crestron
Database).
Fixed bug where devices that had a module name (.cmc file) longer than 50
characters would not be saved properly.
Fixed rare bug where application would crash when Module and Enclosure Wizard
was configured to place the control processor in a room that had no enclosure.
v2.5.1
Fixed bug where there was no way to replace a C2ENET-1 card with a C2ENET-2
card (bug was addressed previously, but still did fix problem)
Fixed bug where application would complain if user database file was missing.
Fixed bug where changing ML-600 RF ID would cause invalid compiled file.