still defaulting to 80% (instead of 100%).
v2.4.2 (Build 20070323:2)
• Fixed bug in Realtime View where the Raise/Lower buttons for the “Equipment
Room, All Room Lights” device would send a raise/lower command to all lighting
loads in the entire project.
• Fixed bug where user would be prompted to upload the scheduler data files on each
upload, even if there were no scheduled events in the project.
• Fixed bug where answering No to the “Upload Scheduler Data Files?” message box
would prevent the learnable lighting master data file from being sent. This could
affect synchronizing learnable lighting.
• Fixed bug where the InfiNET Configuration dialog could be opened even if there was
no project opened.
v2.4.2 (Build 20070322:1)
• Fixed crash when launching Module and Enclosure Assignment Wizard
• Fixed crash that could occur during upload if an error occurred.
• Add 16A breakers to the list of available breaker sizes for systems with a Line
Voltage setting of 220V, 230V, or 240V.
• Changed the default breaker size to 13A (was 10A) for systems with a Line Voltage
setting of 220V, 230V, or 240V.
• Changed default value for “Derating Factor” to 100% for systems with a Line Voltage
setting of 220V, 230V, or 240V.
• Disabled the “Derating Factor” text box for 120V systems (value is fixed at 80% as
per NEC).
v2.4.1
• Fixed bug where learnable buttons that have no corresponding feedback LED that
have the “Single Press + Dim” and “Toggle + Dim” button model will cause a compile
error during the Build process.
• In Realtime View, the Start Flashing button is now disabled for the All Room Lights
devices.
• Fixed crash when clicking the Rename Calendar button on the Scheduled Event
dialog when the project contains no existing Calendars.
• Fixed bug in Programming View where Global Preset options (e.g. Special Run
Behavior) were being displayed even when the Global Presets node was not
selected on the tree.
• The Load Wiring Report now shows the proper label colors for the CLTI terminal
blocks.
• Fixed bug in Realtime View where the Start Flashing button was not working for
loads attached to a CLW-DIM*.
• Fixed bug where generating system documentation would fail if a project had been
converted from 120V to 220-240V (or vice versa).
• Fixed bug where importing an archive containing a user module (.umc) would
generate an error message that user module could not be found (would be found if
application was restarted).
• Added message box to confirm that files have been transferred when selecting
Upload Run-time Data from the context menu in Finish View (when right-clicking on
control processor in tree).
• Fixed bug where sometimes devices that were renamed or moved would not have
their name/location updated in the Finish View tree.