infiNET EX Thermostat (Fan Coil Unit): CHV-TSTATEX-FCU Operations & Installation Guide – DOC. 7206C
3. Feed HVAC wiring from the electrical box through the hole in the center of
the rear plate so it can be connected to the proper terminals on the
CHV-TSTATEX-FCU after the thermostat is mounted.
CAUTION: Excess wire pinched between the CHV-TSTATEX-FCU and
electrical box could cause a short circuit. Make sure that all excess wire is
completely inside the electrical box and not between the box and the
CHV-TSTATEX-FCU.
NOTE: To ensure accurate temperature readings, avoid drafts in the back
of the unit by plugging the wire hole with insulation.
4. Make sure unit is correctly oriented and place it in the electrical box.
5. Attach the CHV-TSTATEX-FCU rear plate to the electrical box using the
two included #06-32 x 1” pan head screws.
CAUTION: Do not press on the LCD display during mounting, as this may
cause the screen to crack.
6. Attach the front plate.
7. Carefully remove the warning label from the LCD display.
8. Insert batteries and attach the battery compartment cover.
CAUTION: Replace all batteries in the device at the same time. Mixing
old and new batteries in the device may result in battery leakage and
equipment damage.
NOTE: Crestron has provided small slots on either side of the battery cover,
designed to allow a flat head screwdriver to be inserted to assist in removal.
9. Turn HVAC system power ON.
Installation into Electrical Box
Rear Plate
Screws
#06-32 x 1"
Battery
Compartment Cover
Screwdriver Slots
Front Plate
Comentarios a estos manuales